6.4: Life Cycle Cost Analysis

  • Page ID
    47187
  • \( \newcommand{\vecs}[1]{\overset { \scriptstyle \rightharpoonup} {\mathbf{#1}} } \)

    \( \newcommand{\vecd}[1]{\overset{-\!-\!\rightharpoonup}{\vphantom{a}\smash {#1}}} \)

    \( \newcommand{\id}{\mathrm{id}}\) \( \newcommand{\Span}{\mathrm{span}}\)

    ( \newcommand{\kernel}{\mathrm{null}\,}\) \( \newcommand{\range}{\mathrm{range}\,}\)

    \( \newcommand{\RealPart}{\mathrm{Re}}\) \( \newcommand{\ImaginaryPart}{\mathrm{Im}}\)

    \( \newcommand{\Argument}{\mathrm{Arg}}\) \( \newcommand{\norm}[1]{\| #1 \|}\)

    \( \newcommand{\inner}[2]{\langle #1, #2 \rangle}\)

    \( \newcommand{\Span}{\mathrm{span}}\)

    \( \newcommand{\id}{\mathrm{id}}\)

    \( \newcommand{\Span}{\mathrm{span}}\)

    \( \newcommand{\kernel}{\mathrm{null}\,}\)

    \( \newcommand{\range}{\mathrm{range}\,}\)

    \( \newcommand{\RealPart}{\mathrm{Re}}\)

    \( \newcommand{\ImaginaryPart}{\mathrm{Im}}\)

    \( \newcommand{\Argument}{\mathrm{Arg}}\)

    \( \newcommand{\norm}[1]{\| #1 \|}\)

    \( \newcommand{\inner}[2]{\langle #1, #2 \rangle}\)

    \( \newcommand{\Span}{\mathrm{span}}\) \( \newcommand{\AA}{\unicode[.8,0]{x212B}}\)

    \( \newcommand{\vectorA}[1]{\vec{#1}}      % arrow\)

    \( \newcommand{\vectorAt}[1]{\vec{\text{#1}}}      % arrow\)

    \( \newcommand{\vectorB}[1]{\overset { \scriptstyle \rightharpoonup} {\mathbf{#1}} } \)

    \( \newcommand{\vectorC}[1]{\textbf{#1}} \)

    \( \newcommand{\vectorD}[1]{\overrightarrow{#1}} \)

    \( \newcommand{\vectorDt}[1]{\overrightarrow{\text{#1}}} \)

    \( \newcommand{\vectE}[1]{\overset{-\!-\!\rightharpoonup}{\vphantom{a}\smash{\mathbf {#1}}}} \)

    \( \newcommand{\vecs}[1]{\overset { \scriptstyle \rightharpoonup} {\mathbf{#1}} } \)

    \( \newcommand{\vecd}[1]{\overset{-\!-\!\rightharpoonup}{\vphantom{a}\smash {#1}}} \)

    \(\newcommand{\avec}{\mathbf a}\) \(\newcommand{\bvec}{\mathbf b}\) \(\newcommand{\cvec}{\mathbf c}\) \(\newcommand{\dvec}{\mathbf d}\) \(\newcommand{\dtil}{\widetilde{\mathbf d}}\) \(\newcommand{\evec}{\mathbf e}\) \(\newcommand{\fvec}{\mathbf f}\) \(\newcommand{\nvec}{\mathbf n}\) \(\newcommand{\pvec}{\mathbf p}\) \(\newcommand{\qvec}{\mathbf q}\) \(\newcommand{\svec}{\mathbf s}\) \(\newcommand{\tvec}{\mathbf t}\) \(\newcommand{\uvec}{\mathbf u}\) \(\newcommand{\vvec}{\mathbf v}\) \(\newcommand{\wvec}{\mathbf w}\) \(\newcommand{\xvec}{\mathbf x}\) \(\newcommand{\yvec}{\mathbf y}\) \(\newcommand{\zvec}{\mathbf z}\) \(\newcommand{\rvec}{\mathbf r}\) \(\newcommand{\mvec}{\mathbf m}\) \(\newcommand{\zerovec}{\mathbf 0}\) \(\newcommand{\onevec}{\mathbf 1}\) \(\newcommand{\real}{\mathbb R}\) \(\newcommand{\twovec}[2]{\left[\begin{array}{r}#1 \\ #2 \end{array}\right]}\) \(\newcommand{\ctwovec}[2]{\left[\begin{array}{c}#1 \\ #2 \end{array}\right]}\) \(\newcommand{\threevec}[3]{\left[\begin{array}{r}#1 \\ #2 \\ #3 \end{array}\right]}\) \(\newcommand{\cthreevec}[3]{\left[\begin{array}{c}#1 \\ #2 \\ #3 \end{array}\right]}\) \(\newcommand{\fourvec}[4]{\left[\begin{array}{r}#1 \\ #2 \\ #3 \\ #4 \end{array}\right]}\) \(\newcommand{\cfourvec}[4]{\left[\begin{array}{c}#1 \\ #2 \\ #3 \\ #4 \end{array}\right]}\) \(\newcommand{\fivevec}[5]{\left[\begin{array}{r}#1 \\ #2 \\ #3 \\ #4 \\ #5 \\ \end{array}\right]}\) \(\newcommand{\cfivevec}[5]{\left[\begin{array}{c}#1 \\ #2 \\ #3 \\ #4 \\ #5 \\ \end{array}\right]}\) \(\newcommand{\mattwo}[4]{\left[\begin{array}{rr}#1 \amp #2 \\ #3 \amp #4 \\ \end{array}\right]}\) \(\newcommand{\laspan}[1]{\text{Span}\{#1\}}\) \(\newcommand{\bcal}{\cal B}\) \(\newcommand{\ccal}{\cal C}\) \(\newcommand{\scal}{\cal S}\) \(\newcommand{\wcal}{\cal W}\) \(\newcommand{\ecal}{\cal E}\) \(\newcommand{\coords}[2]{\left\{#1\right\}_{#2}}\) \(\newcommand{\gray}[1]{\color{gray}{#1}}\) \(\newcommand{\lgray}[1]{\color{lightgray}{#1}}\) \(\newcommand{\rank}{\operatorname{rank}}\) \(\newcommand{\row}{\text{Row}}\) \(\newcommand{\col}{\text{Col}}\) \(\renewcommand{\row}{\text{Row}}\) \(\newcommand{\nul}{\text{Nul}}\) \(\newcommand{\var}{\text{Var}}\) \(\newcommand{\corr}{\text{corr}}\) \(\newcommand{\len}[1]{\left|#1\right|}\) \(\newcommand{\bbar}{\overline{\bvec}}\) \(\newcommand{\bhat}{\widehat{\bvec}}\) \(\newcommand{\bperp}{\bvec^\perp}\) \(\newcommand{\xhat}{\widehat{\xvec}}\) \(\newcommand{\vhat}{\widehat{\vvec}}\) \(\newcommand{\uhat}{\widehat{\uvec}}\) \(\newcommand{\what}{\widehat{\wvec}}\) \(\newcommand{\Sighat}{\widehat{\Sigma}}\) \(\newcommand{\lt}{<}\) \(\newcommand{\gt}{>}\) \(\newcommand{\amp}{&}\) \(\definecolor{fillinmathshade}{gray}{0.9}\)

    Performing a life-cycle cost analysis (LCC) gives the total cost of a lighting system—including all expenses incurred over the life of the system. This analysis can be applied not only to lighting but for most of the appliances, automobiles, heating systems, and so on, when two systems are compared to determine the most cost effective options.

    There are two reasons to do an LCC analysis:

    1. To compare different systems, or bulbs in this case.
    2. To determine the most cost-effective system or a bulb.

    For some lighting systems, one of two situations may exist:

    1. The initial cost may be high but the energy costs will be low over its lifetime.
    2. The initial cost to buy a bulb or a system and the energy or the maintenance costs may be low, but the useful life of such a bulb or system may be short. (In this case, we may have to replace the appliance several times to get the same useful life as the other option.)

    Therefore, a life-cycle cost (LCC) analysis can be helpful for comparing the total costs incurred over the lifetime of a lighting system. It is, in essence, calculating all the costs incurred to buy, maintain, and run the system over its lifetime.

    \[ Life \, Cycle \, Costs = (Cost \, to \, buy) + (Cost \, to \, maintain \, it \, (if \, any) + (Cost \, of \, energy \, to \, run \,it) + (Replacement \, costs) - (Any \, salvage \, value) \]

    In equation 6.4.1,

    • Cost to buy is the purchase price of the bulb or the system.
    • Cost to maintain is the cost incurred to maintain it in good operating condition. (For example in the case of a car, an engine oil change every 3,000 miles is part of maintenance costs.)
    • Cost of energy is the energy or the fuel it takes to run the appliance or bulb for its lifetime.
    • Replacement cost is the cost to replace the bulb. If bulb A has a life of 1000 hrs and bulb B has a life of 10,000 hours, then Bulb A needs to be replaced 10 times to get the same useful life period as that of bulb B. Therefore, 10 A bulbs need to be purchased for each B Bulb.

    Table 6.4.1 shows a life cycle cost analysis in comparing an incandescent bulb and a compact fluorescent light (CFL).

    Table 6.4.1. Life cycle cost analysis: incandescent vs. CFL bulb

      Incandescent CFL
    Rating 60 Watts 15 Watts
    Lumen output 865 Lumens 900 Lumens
    Cost of one bulb $0.60 $5.00
    Lifetime of one bulb 1,000 hr 10,000 hr
    Bulbs needed for a lifetime of 10,000 hr 10 bulbs 1 bulb
    Cost of bulbs needed for 10,000 hr $6.00 $5.00
    Energy consumption for 10,000 hr 600 kWh 150,000 kWh
    Price of electricity $0.085 $0.085
    Cost of electricity for 10,000 hr $51.00 $12.75
    Total life cycle costs to own and operate bulbs for 10,000 hr $(51.00 + 6.00) = $57.00 $(12.75 + 5.00) = $17.75

    Additional Information

    This analysis shows clearly that each incandescent bulb replaced with a CFL that would fit into a regular incandescent bulb fixture would save about $39.25 over 10,000 hours of operation. Imagine the number of bulbs that you have at home: living room, kitchen, bath rooms, bed rooms, table lights, floor lamps, ceiling lights, closets, garage, basement, and so on. There are energy saving options all over the home.

    Although they save energy, there are some disadvantages with CFLs:

    • They are often physically larger than the incandescent bulbs they replace and simply may not fit the lamp.
    • The light is generally cooler—less yellow—than incandescent light bulbs. This may result in less than pleasing contrast with ordinary lamps and ceiling fixtures. Newer models have been addressing this issue.
    • Some types (usually iron ballasts) may produce an annoying flicker.
    • Ordinary dimmers cannot be used with compact fluorescents.
    • Like other fluorescents, operation at cold temperatures (under around 50–60 degrees F) may result in reduced light output.
    • There may be an audible buzz from the ballast.

    This page titled 6.4: Life Cycle Cost Analysis is shared under a CC BY-NC-SA 4.0 license and was authored, remixed, and/or curated by Sarma V. Pisupati (John A. Dutton: e-Education Institute) via source content that was edited to the style and standards of the LibreTexts platform.